Product Features:
· High performance PCS
· High reliability
· >6000 cycles
· Efficient Thermal Management System
· IP55 high protection level
· DC circuit fast fuse protection
· Multi level battery safety management
· LFP battery/solid-state battery
· Independent cabin design
· Hold the microsystem for peak shaving and filling, respond to demand, and switch seamlessly without any gaps;
YH-ESS-100KW-215KWh-100KW MPPT | YH-ESS-120KW-229KWh-120KW MPPT | |
Battery pack section | ||
Rated total energy | 215kWh | 229kWh |
Rated voltage | 768V DC | 819.2V DC |
Voltage range | 600~876V DC | 640~934.4V DC |
Standard charging/discharging rate | 0.5C @ continuous | 0.5C @ continuous |
Maximum charging/discharging rate | 1C @ continuous | 1C @ continuous |
Inverter section | ||
Grid connected output rated power | 100000 | 120000 |
Maximum grid connected output apparent power (VA) * 2 | 100000 | 120000 |
Rated output voltage (V) | 380V,3L/N/PE | 380V,3L/N/PE |
Output voltage frequency (Hz) | 50HZ/60HZ | 50HZ/60HZ |
Maximum grid connected output current (A) | 260A | 300A |
Maximum off grid output power (VA) * 3 | 50000 | 60000 |
Maximum off grid output current (A) | 140A | 150 |
Off grid rated output voltage (V) | 380V,3L/N/PE | 380V,3L/N/PE |
Off grid rated output voltage frequency (Hz) | 50HZ/60HZ | 50HZ/60HZ |
Maximum input power of photovoltaic (W) | 100000 | 120000 |
Maximum input voltage of photovoltaic (V) * 1 | 1000 | 1000 |
MPPT voltage range (V) * 2 | 180~950v | 180~950v |
Starting voltage (V) | 150v | 150v |
Maximum input current per MPPT channel (A) | 45A/45A | 45A/45A |
Maximum short-circuit current per MPPT channel (A) | 45A/45A | 45A/45A |
MPPT quantity | 8 | 8 |
Number of input strings per MPPT channel | 2/2/2/2/2/2/2/2 | 2/2/2/2/2/2/2/2 |
Maximum efficiency 98.40% | 0.984 | 0.984 |
Total voltage waveform distortion rate (@ linear load) | <3% | <3% |
Cabinet parameters | ||
Weight | 2500kg | 2600kg |
Dimensions (width * height * depth) | 1450*1050*2200mm | 1450*1050*2200mm |
Protection level | IP54 | IP54 |
Cooling method | Air conditioning cooling | Air conditioning cooling |
Ambient temperature | Charging:0 ℃~55 ℃/Discharge: -20 ℃~60 ℃/Storage: -10 ℃~45 ℃ | Charging:0 ℃~55 ℃/Discharge: -20 ℃~60 ℃/Storage: -10 ℃~45 ℃ |
Operating humidity | 5~95%, relative humidity | 5~95%, relative humidity |
Contact method | CAN, RS485, RS232 | CAN, RS485, RS232 |
Alarm and protection | Capabilities | Capabilities |
Indicator light status | Alarm/running/SOC | Alarm/running/SOC |
Installation method | Integrated cabinet type | Integrated cabinet type |